J杭州炬卡电器有限公司Solar Cold Chain Refrigeration Get a Quote
Home / Quality
Part Three — Quality Control

Quality is a process, not an inspection

On a solar cabinet, a small refrigeration leak or a soft foam layer is not a cosmetic problem — it is the difference between food staying frozen overnight and food being lost. Our quality system is built around that reality.

Certification
Management Discipline

Production stays with production. Quality stays with quality.

The company maintains a dedicated process and quality assurance department, which has produced written process standards for each operation. The production department strictly follows those documents.

No product may be packed or warehoused unless a quality inspector has confirmed it as passing. The separation of the two functions is deliberate: the people who build the cabinet do not get to decide whether it passes.

Written process standards Dedicated QA department Inspection before packing Traceable test records
The Refrigeration Standard

Four specific commitments on every unit

These are the checks that decide whether a cabinet still performs in year five. They are written into the process documents, not applied at the inspector's discretion.

Nitrogen purge before connection

Before the piping is joined, both the condenser section and the evaporator section are purged with nitrogen gas. This guarantees the cleanliness of the circuit, which is what prevents later blockage and moisture damage.

Vacuum standard of 20 Pa or lower

Every unit must reach 20 Pa or better. A unit that does not reach the standard cannot be charged — the machine does not allow it. Incomplete evacuation is the most common cause of early refrigeration failure.

Refrigeration testing to written standards

Probe placement requirements and the accepted test criteria for each ambient temperature are defined in detailed written documents, so results are comparable between units and between batches.

Two leak tests per unit

Each unit is checked with the INFICON high-sensitivity leak detector twice — once in the unpowered state and once while running. A joint that only leaks when the system is warm is caught by the second pass.

Laboratory and test room
Laboratory & Test Room

Two rooms, two different jobs

Calibration: a reliable in-house laboratory confirms the accuracy of the declared refrigeration parameters, so a catalogue figure reflects a measured result rather than a target.

Consistency: a constant-temperature test room tests every unit under identical ambient conditions before delivery. This is what keeps performance stable across batches and seasons — a cabinet tested in July and one tested in January still meet the same standard.

Refrigeration and control components are sourced from dependable brands within the industry and then confirmed through severe-condition testing in the laboratory, so the product still operates correctly across very different regional climates and duty cycles.

Component Quality

Where the upgrade is, and why it matters

Component specification is the easiest place for a supplier to reduce cost invisibly. These are the differences we maintain.

Condenser tube 6.0 mm

Thicker than the 4.78 mm tube used by ordinary manufacturers. On the BD/BC-208 the condenser carries 120 wires, thicker and denser, for better dissipation.

All-copper motor windings

Compressor motor coils are guaranteed 100 % copper rather than aluminium-substitute windings, which matters for lifetime and for efficiency on a limited solar supply.

Aluminium controller housing

Every compressor controller is housed in a large aluminium case, with a fan blowing directly onto it to keep the controller temperature down and the compressor stable.

16 A industrial plug

High-current plug that does not overheat or burn out — a common failure point on cheaper cabinets in hot climates.

Pure white nylon castors

No regrind material in the wheels, so they stay true and last far longer under daily movement on rough floors.

10-year LED corn lamp

Interior lighting uses a high-grade LED corn lamp rated for around ten years, with much lower power draw than a fluorescent tube — relevant on a solar system.

Compliance

Certification and market documentation

Certificates and test reports are issued per order, matched to the destination market and to the specific model and voltage configuration.

Certificate CE Certificate CE 2 Quality certificate High-tech enterprise certificate
Documentation requirements differ by country. Send us the destination market and the model number, and we will confirm which certificates and reports can be provided with the shipment.

Need the test documentation for a specific model?

Tell us the model and the destination market, and we will confirm exactly which certificates and test reports apply.

Request Documentation